AER ALPEK

AER/ALPEK 
  
STANDARD: TS 11654
TECHNICAL DATA:Max. Operating Temp.: 90 °C 
 Minimum Bending Radius: 15xD
 Max. Short Circuit Temp.: 250 °C
 Rated Voltage: 0,6/1 kV
 Test Voltage: 2,5 kV
CONSTRUCTION:                  1. Stranded Aluminium Conductor
 2. PE veya XLPE Insulation
 3. Aluminium Alloy Hanger Wire
AER ABC 1

APPLICATION

Used in rural and wooded areas for village electrical systems. Safer against accidental contact with bare overhead conductors.

Contact Form

 

AER ALPEK
TECHNICAL TABLE

Nominal Cross Section (mm²)Diameter of Conductor (mm)Diameter of Messenger (mm)Conductor DC Resistance at 20˚C (ohm/km)Rope DC Resistance at 20˚C (ohm/km)Net Weight (kg/km) Aprox.Current Carrying Capacity In Conductor(A)
1x16+254.55.91.911.3814077
1x25+356.26.91.20.98620097
1x35+507.18.10.8680.72280120
1x16+1x16+254.55.91.911.3821077
3x16+254.55.91.911.3828077
3x25+356.36.91.20.98640097
3x35+507.28.10.8680.72560120
3x50+708.19.70.6410.493730146
3x70+959.811.40.4430.3631030187
3x120+9512.6110.2530.3631150263
3x16+1x16+254.55.91.911.3835077
3x25+1x16+356.36.91,20/1,910.98648097
3x35+1x16+507.28.10,868/1,910.72630120
3x50+1x16+707.19.70,641/1,910.493800146
3x70+1x16+959.811.40,443/1,910.3631100187
4x16+254.55.91.911.3835077
4x25+356.16.91.20.98651097